Reactions can be employed to manage access, have standalone visual and/or audial alerts, and/or to supplement Checkpoint and Parking modes with alerts.
When supplementing Checkpoint and/or Parking modes with Reactions, please, manage barrier/gate via checkpoint settings. In this case you can also employ relay to fire additional devices (e.g. traffic lights) via Reactions.
You may want to setup multiple reactions. There are two modes of active reactions execution:
run all active reactions, where conditions match;
execute first matching reaction only.
Under Car database > Reaction click Add and
name the reaction and describe it;
select event type and set conditions the reaction would fire on (details are in the following sections);
assign one or more reaction methods;
optionally assign a time schedule for the reaction;
click Ok to save the settings.
Some methods are not available for specific event types.
Certain conditions are only available when relevant operation mode is activated under Settings > General.
The reaction will fire if every checked condition is fulfilled.
Plate number: exact match required
Type of car or group options: LP is not in database or LP belongs to a specified group or LP doesn’t belong to a specified group.
Channel / Zone: LP is recognised in a specified zone of a particular channel.
Change Channel / Zone: LP is recognized in first specified Channel / Zone and then in the second specified Channel / Zone.
Direction: when LP movement direction is either Entry or Exit or Undetermined.
The reaction will fire if every checked condition is fulfilled.
Checkpoint: event is associated with a particular checkpoint.
Type of car or group options: LP is not in database or LP belongs to a specified group.
Direction: Try entry (attempt to enter) or Entry (confirmed drive-in) or Try exit (attempt to leave) or Exit (confirmed drive-out).
Duration of stay: longer than H hours and M minutes and optionally shorter than X hours and Y minutes.
Access control: Allowed or Denied; if Denied then additional filtering is available: denied since LP wasn’t allowed at the time given;
denied for visits limit exceeded; denied for duration condition violation.
Select parking to apply the reaction to.
The reaction will fire if every checked condition is fulfilled.
Type of car or group options: LP is not in the database or LP belongs to a specified group.
Cars on the territory: more than X cars and optionally less than Y cars.
Reaction will fire if any LP appears on a specified Channel at least a specified number of times within the time interval specified.
Reaction scheduling is not available for this type of reaction.
Available only in NumberOk Enterprise edition.
Select specific violation to apply reaction to.
The reaction will fire if every checked condition is fulfilled.
Plate number: exact match required
Type of car or group options: LP is not in the database or LP belongs to a specified group or LP doesn’t belong to a specified group.
Channel / Zone: LP is recognised in a specified zone of a particular channel.
Direction: when LP movement direction is either Entry or Exit or Undetermined.
The reaction will fire if every checked condition is fulfilled and speed limit set under Settings >General >Traffic rules > Average speed is exceeded.
Plate number: exact match required
Type of car or group options: LP is not in the database or LP belongs to a specified group or LP doesn’t belong to a specified group.
Channel / Zone: LP is recognised in a specified zone of a particular channel.
Direction: when LP movement direction is either Entry or Exit or Undetermined.